Details of this Shed

Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 4,600 kg
Span – Main Building: 9 metres
Length – 20 metres (5 Bays of 4 metres each)
Height – 3 metres (Low Side), 3.95 metres (High Side)
Roof Type – Skillion, 06 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – UNSLOTTED 115 Quad Gutter. We have calculated the number of [Supplied by Others] downpipes required for: Right Side = 6.
Roller Doors – Two (2) COLORBOND® steel 2.57m high x 2.75m wide roller doors (roller door is wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. Two (2) COLORBOND® steel 2.5m high x 2.75m wide roller doors (roller door is wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport.
PA Doors – One (1) single skin Deluxe COLORBOND® steel door with keyed lockset and lever handle to one side;
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Three (3) 900h x1200w windows (supply of the window is NOT included).
Dividing Walls – One (1) structural wall coloured red running across the span of the building between bays 1 & 2. COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting. This wall will be the colour selected for internal walls. This wall is structural – they must be installed in the location shown. They cannot be moved at any time.
Open Bays – Two (2) 4m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the left-end-wall-mullions have been removed. Refer to the Layout attached.
Bracing – The building will have Knee braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.935m (Left Side), 2.092m (Right Side) .
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.

Site Design Specifications

Site – Eastern NSW 2800 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45 m/s; Region A1; TC = 2.0; Mt = 1; Mc = 1; Ms = 1.0; giving a Vdes of 41 m/s.
Snow Load – Snow loading has been allowed for a site with a maximum AHD of 801.87m in the Central Tablelands, NSW for a sub alpine site.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.

Pricing at Feb 2024

Kit Price – $31,972.73
GST – $3,197.27
Delivery – FREE*
Pay-on-Time discount – ($3,520.00)#
TOTAL (inc GST) – $31,650.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.

REFERENCE # : 2402132

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.