REFERENCE # : 2207125

BUY A SHED COURSE:

The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.

REFERENCE # : 2207125

Details of this Shed 

Weight – Approximately: 1,300 kg
Span – 8 metres
Length – 10 metres (3 Bays: 3.33 metres, 3.33 metres, 3.33 metres)
Height – 2.5 metres
Roof Type – Gable, 10 degree pitch
Roof – ZINCALUME® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – ZINCALUME® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – 115 High Front quad gutter – Unslotted . Nominal downpipe spacing = 3.3m.
Open Bays – Six (6) 3.33m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the end-wall-mullions have been removed. Refer to the Layout attached.
Bracing – The building will have Apex braces. Minimum internal apex clearance is: 2.736m.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Cast-in Brackets

Site Design Specifications 

Site – Southern VIC 3922 Australia
Building Class – 10
Importance Level – 2 with a Vr of 45 m/s
Design Wind Criteria – Region A1; TC = 2.5; Mt = 1; Ms = 1; giving a Vdes of 39.2 m/s.
Other Design Factors – No Snow Loading allowed. No Earthquake Loading allowed.
Roof Only – Less than 50% filled under

PRICING AT JULY 2022

Kit Price – $8,527.27
GST – $852.73
Delivery – FREE*
Promotional Discount (Mid-Year Shed Sale) – ($710.00)
TOTAL (inc GST) – $8,670.00
* subject to standard delivery area

 

REFERENCE # : 2207125

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.