REFERENCE # : 2110031-1
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2110031-1
Details of this Shed
Weight – Approximately: 5,100 kg
Span – 7 metres
Length – 24 metres (7 Bays: 3 metres, 3 metres, 4 metres, 4 metres, 4 metres, 3 metres, 3
metres)
Height – 3.85 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Roller Doors – One (1) COLORBOND® steel 3.2m high x 2.75m wide roller door supplied with a planetary gearing system (roller door is wind rated). One (1) COLORBOND® steel
2.8m high x 2.5m wide roller door (roller door is wind rated). Refer to the General
Specification (# Access Doors) in relation to opening sizes. The Roller Doors are
boxed or steel wrapped for protection during transport. Refer to the Building
information for details on Industrial Door Handing.
PA Doors – One (1) 2040h x820w COLORBOND® steel door. Single skin metal clad door with COLORBOND® steel facings and fold-down vertical sides for strength and
appearance. On a welded RHS frame, the door is pre-hung into a powdercoated
frame. Supplied with a Knob/Knob entrance set;
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit One (1) 900h x1200w window (supply of the window is NOT included).
Dividing Walls – Two (2) running across the span of the building. COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting.
Open Bays – Eight (8) 3m open bays – along the sides of the steel building. Refer to Layout
(attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the end-wall-mullions have been removed. Refer to the Layout attached.
Bracing – The building will have Knee braces. Minimum internal knee clearances are: Main
Building 2.865m.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width. Brackets are provided so that the Z is bolted through the web.
Fixing to Concrete – Cast-in Brackets.
Site Design Specifications
Site – Northern QLD 4814 Australia
Building Class – 10
Importance Level – 2 with a Vr of 69.3 m/s
Design Wind Criteria – Region C; TC = 2.5; Mt = 1; Ms = 1; giving a Vdes of 57.3 m/s.
Other Design Factors – No Snow Loading allowed. No Earthquake Loading allowed.
PRICING AT OCT 2021
Kit Price – $33,645.45
GST – $3,364.55
Delivery – FREE*
Promotional Discount – ($2,780.00)
TOTAL (inc GST) – $34,230.00
* subject to standard delivery area
REFERENCE # : 2110031-1
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.