REFERENCE # : 2402049
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2402049
Details of this Shed
Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 1,100 kg
Span – Main Building: 4 metres
Length – 6 metres (2 Bays of 3 metres each)
Height – 2.6 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – UNSLOTTED 150 Hi Front Quad Gutter. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 1. Right Side = 1.
Roller Doors – One (1) COLORBOND® steel 2.11m high x 2.4m wide roller door (roller door is wind rated). Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Door is boxed or steel wrapped for protection during transport.
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Two (2) 900h x1200w windows and One (1) 2100h x1800w glass sliding door (the supply of windows is NOT included).
Insulation – Lightweight 50-60mm Insulated Roofing Blanket, or equivalent performance specification. Insulation is a glass wool blanket with a reinforced laminated thermofoil face to one side. (Performance specification (R Value) change dependent on the ventilation. Insulation to the roof of the main building. Safety wire is provided to the roof area only.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – Central Coast QLD 4714 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 57 m/s; Region B; TC = 2.5; Mt = 1.01; Mc = 1.05; Ms = 1.0; giving a Vdes of 47.3 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.
Pricing at Feb 2024
Kit Price – $8,254.55
GST – $825.45
Delivery – FREE*
Pay-on-Time discount – ($910.00)#
TOTAL (inc GST) – $8,170.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2402049
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.