REFERENCE # : 2409022-2

40m x 30m x 5m Zincalume Roof Only Arena Cover with 10m Awning

BUY A SHED COURSE:

The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.

REFERENCE # : 2409022-2

Details of this Shed

Building Class – 10a A non-habitable building including a private garage, carport, shed or the like. (Refer NCC A6G11)
Weight – Approximately: 29,200 kg
Span – Main Building: 30 m
Length – 40 m (8 Bays of 5 m each)
Height – 5 m
Roof Type – Gable, 10 degrees
Roof – ZINCALUME® steel TRIMCLAD® 0.42 BMT sheeting, BlueScope
Walls & Trims – ZINCALUME® steel TRIMCLAD® 0.42 BMT sheeting, BlueScope
Gutters – ZINCALUME® GUTTER-01. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 41. Right Side = 25 (main building), 41 (leanto).
Open Bays – Sixteen (16) 5m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the end-wall-mullions have been removed. Refer to the Layout attached.
Bracing – The building will have Knee and Apex braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Left Leanto 2.356m, Main Building 2.751m. Estimated internal apex clearance is: 6.138m.
Left Lean-to
Span – 10m
Drop – No drop
Pitch – 6 degrees
Length – Starting bay 1 for 8 bays
Height of External Lean-to wall – 3.95m
Eight (8) 5m open bays – along the sides of the leanto. Six (6) 3.33m open bays on the ends of the leanto. Refer to Layout (attached) for location & height clearances.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Columns embedded into the concrete footings.

Site Design Specifications

Site – Eastern NSW 2421 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45 m/s ; Region A2; TC = 2.5; Mt = 1; Mc = 1; Ms = 1.0; giving a Vdes of 39.7 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.09 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.
Roof Only – Less than 50% filled under

Pricing at Sep 2024

Kit Price – $172,972.73
GST – $17,297.27
Delivery – $10.00
Pay-on-Time discount – ($14,280.00)#
TOTAL (inc GST) – $176,000.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.

REFERENCE # : 2409022-2

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.