Details of this Shed

Building Class – 10a A non-habitable building including a private garage, carport, shed or the like. (Refer NCC A6G11)
Weight – Approximately: 4,700 kg
Span – Main Building: 12 m
Length – 12 m (3 Bays of 4 m each)
Height – 3.6 m
Roof Type – Gable, 10 degrees
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT sheeting, BlueScope
Gutters – COLORBOND® GUTTER-05. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 4.
Roller Doors – Three (3) COLORBOND® steel 3m high x 2.9m wide roller doors (roller door is wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. Refer to
the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport.
PA Doors – One (1) Larnec 2040h x 820w Single skin metal clad pre-hung door with COLORBOND® steel® steel facings and fold-down vertical sides for strength and appearance. Powder coated welded RHS frame.
Supplied with a Knob/Lever entrance set. 180 degrees opening and reversible handing;
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Five (5) 900h x1800w windows (supply of the window and glass sliding doors is NOT included).
Open Bays – Three (3) 4m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Bracing – The building will have Knee and Apex braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.688m. Estimated internal apex clearance is: 4.031m. Side Walls bracing will be supplied as cable.
Right Lean-to
Span – 4m
Drop – No drop
Pitch – 6 degrees
Length  – Starting bay 1 for 3 bays
Height of External Lean-to wall – 3.18m
Leanto is fully sheeted.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured

Site Design Specifications

Site – South Eastern QLD 4212 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 57 m/s ; Region B; TC = 3.0; Mt = 1.07; Mc = 1; Ms = 1.0; giving a Vdes of 48.1 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.

Pricing at Aug 2024

Kit Price – $33,145.45
GST – $3,314.55
Delivery – FREE*
Pay-on-Time discount – ($2,740.00)#
TOTAL (inc GST) – $33,720.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.

REFERENCE # : 2409015

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.