REFERENCE # : 2406118-1
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2406118-1
Details of this Shed
Building Class – 10a A non-habitable building including a private garage, carport, shed or the like. (Refer NCC A6G11)
Weight – Approximately: 7,000 kg
Span – Main Building: 6 m
Length – 14 m (4 Bays of 3.5 m each)
Height – 6 m
Roof Type – Gable, 22.5 degrees
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – COLORBOND® GUTTER-04. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 2 (main building), 3 (leanto). Right Side = 2 (main building), 3 (leanto).
Roller Doors – Two (2) COLORBOND® steel 2.1m high x 2.4m wide roller doors (roller door is wind rated). One (1) COLORBOND® steel 2.55m high x 3m wide roller door (roller door is wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport.
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Two (2) 900h x1200w windows (supply of the window is NOT included).
Open Bays – Eight (8) 3.5m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Bracing – The building will have Knee and Apex braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 5.234m. Estimated internal apex clearance is: 6.485m.
Left & Right Lean-to
Span – 4m
Drop – 2 metres from eave height
Pitch – 10 degrees
Length – Starting bay 1 for 4 bays
Height of External Lean-to wall – 3.3m
Left end sheeting – Yes
Right end sheeting – Yes
Outside wall sheeting – Yes
Inside wall sheeting – No
Mezzanine – Four (4) bays, starting at bay One (1). Height under joist to be 3m, with a clearance under the bearer of 2.65m. Steel bearers and joists only. Bearers supported by Zero (0) to Two (2) mid columns. Stairs, balustrading and timber flooring supplied by others. Allowable floor load is 3.0kPa uniformly distributed. 300kg/m2 uniformly distributed.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – South West WA 6558 Australia
NCC Version – NCC 2019
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45 m/s ; Region A4; TC = 2.5; Mt = 1; Ms = 1.0; giving a Vdes of 39.9 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.1 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.
Pricing at June 2024
Kit Price – $47,690.91
GST – $4,769.09
Delivery – FREE*
Pay-on-Time discount – ($3,940.00)#
TOTAL (inc GST) – $48,520.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2406118-1
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.