REFERENCE # : 2404007

12m x 25m x 6m Region B Shed With Mezzanine Floor, Roller Doors and PA Doors

BUY A SHED COURSE:

The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.

REFERENCE # : 2404007

Details of this Shed

Building Class – 10A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 13,200 kg
Span – Main Building: 12 metres
Length – 25 metres (5 Bays of 5 metres each)
Height – 6 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – COLORBOND® GUTTER-05. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 7. Right Side = 7.
Roller Doors – Two (2) COLORBOND® steel 5m high x 4m wide roller doors supplied with a planetary gearing system (roller door is wind rated). Three (3) COLORBOND® steel 2.55m high x 2.75m wide roller doors (roller door is wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport. Refer to the Building information for details on Industrial Door Handing.
PA Doors – Two (2) Larnec 2040h x 820w Single skin metal clad pre-hung doors with COLORBOND® steel® steel facings and fold-down vertical sides for strength and appearance. Powder coated welded RHS frame. Supplied with a Knob/Lever entrance set. 180 degrees opening and reversible handing;
Bracing – The building will have Knee and Apex braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 4.263m. Estimated internal apex clearance is: 6.282m.
Mezzanine – Three (3) bays, starting at bay Three (3). Height under joist to be 3m, with a clearance under the bearer of 2.7m. Steel bearers and joists only. Bearers supported by Two (2) mid columns. Stairs, balustrading and timber flooring supplied by others. Allowable floor load is 3.0kPa uniformly distributed. (Suitable for a office for general use or General storage up to 1.2m high – No concentrated loads).
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.

Site Design Specifications

Site – South Eastern QLD 4505 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 57 m/s; Region B; TC = 2.5; Mt = 1; Mc = 1; Ms =
1.0; giving a Vdes of 47.9 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.

Pricing at Apr 2024

Kit Price – $91,454.55
GST – $9,145.45
Delivery – FREE*
Pay-on-Time discount – ($7,550.00)#
TOTAL (inc GST) – $93,050.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.

REFERENCE # : 2404007

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.