REFERENCE # : 2304046
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2304046
Details of this Shed
Weight – Approximately: 4,800 kg
Span – Main Building: 12 metres
Length – 16.5 metres (3 Bays of 5.5 metres each)
Height – 4 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Roller Doors – Two (2) COLORBOND® steel 3.5m high x 3.3m wide roller doors supplied with a planetary gearing system (roller door is wind rated). An internal chain drive has been added to the door to assist with opening and closing the door at heights. One (1) COLORBOND® steel 2.4m high x 2.6m wide roller door (roller door is wind rated). Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport. Refer to the Building information for details on Industrial Door Handing.
PA Doors – One (1) 920mm wide pre-hung double skin COLORBOND® steel door with keyed lockset and lever handle on both sides;
Dividing Walls – One (1) running across the span of the building. COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting. This wall is structural – it must be installed and cannot be moved at any time.
Open Bays – Two (2) 5.5m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the left-end-wall-mullions have been removed. Refer to the Layout attached.
Bracing – The building will have Knee and Apex braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.228m. Estimated internal apex clearance is: 4.328m.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – Central NSW 2830 Australia
Building Class – 10
NCC Version – The Engineer to select NCC 2019 or NCC 2022 as a Performance Standard
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45 m/s; Region A1; TC = 2.5; Mt = 1; Ms = 1; giving a Vdes of 39.2 m/s.
Other Design Factors – No Snow Loading allowed.
Pricing at Apr 2023
Kit Price – $65,272.73
GST – $6,527.27
Delivery – FREE*
Promotional Discount (Beat The Price Rise Before EOFY) – ($5,390.00)
TOTAL (inc GST) – $66,410.00
* subject to standard delivery area
REFERENCE # : 2304046
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.