REFERENCE # : 2410174

10m x 20m x 4m Hay Shed With Office Area, 4m Open Bays and Zincalume Roof

BUY A SHED COURSE:

The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.

REFERENCE # : 2410174

Details of this Shed

Building Class – 10a A non-habitable building including a private garage, carport, shed or the like. (Refer NCC A6G11)
Weight – Approximately: 4,600 kg
Span – Main Building: 10 m
Length – 20 m (5 Bays of 4 m each)
Height – 4 m
Roof Type – Gable, 10 degrees
Roof – ZINCALUME® steel TRIMCLAD® 0.42 BMT sheeting, BlueScope
Walls & Trims – ZINCALUME® steel TRIMCLAD® 0.42 BMT sheeting, BlueScope
Gutters – ZINCALUME® GUTTER-01. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 3. Right Side = 3.
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit One (1) 2100h x2100w glass sliding door and Two (2) 900h x1200w windows (the supply of windows and glass sliding doors NOT included).
Dividing Walls – One (1) structural wall coloured red running across the span of the building between bays 4 & 5. ZINCALUME® steel TRIMCLAD® 0.42 BMT sheeting. This wall will be the colour selected for internal walls. This wall is structural – they must be installed in the location shown. They cannot be moved at any time.
Open Bays – Four (4) 4m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Bracing – The building will have Knee and Apex braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee
clearances are: Main Building 2.484m. Estimated internal apex clearance is: 4.307m.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.

Site Design Specifications

Site – North Western TAS 7330 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45 m/s ; Region A3; TC = 2.5; Mt = 1; Mc = 1; Ms = 1.0; giving a Vdes of 39.2 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.

Pricing at Oct 2024

Kit Price – $28,600.00
GST – $2,860.00
Delivery – FREE*
Pay-on-Time discount – ($2,360.00)#
TOTAL (inc GST) – $29,100.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.

REFERENCE # : 2410174

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.