REFERENCE # : 2307022-3

8m x 12m x 3m Region C, Cyclone Region, Lifestyle Shed With Trimclad Roof and Walls, Roof Ventilators

BUY A SHED COURSE:

The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.

REFERENCE # : 2307022-3

Details of this Shed

Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 3,100 kg
Span – Main Building: 8 metres
Length – 12 metres (4 Bays of 3 metres each)
Height – 3 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – 150 High Front Quad Gutter – Unslotted . Nominal downpipe spacing = 3m.
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Two (2) 1200h x1500w windows, One (1) 600h x600w window, One (1) 2100h x900w window and Two (2) 2100h x2100w glass sliding doors (the supply of windows is NOT included).
Dividing Walls – One (1) structural wall coloured red running across the span of the building between bays 3 & 4. COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting. This wall will be the colour selected for internal walls. This wall is structural – they must be installed in the location shown. They cannot be moved at any time.
Vermin Flashing – PVC Vermin Proofing has been included to the perimeter of the building excluding any openings
Roof Ventilators – Ridge vent (same colour as roof).
Open Bays – Two (2) 3m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the right-end-wall-mullions have been removed. Refer to the Layout attached.
Bracing – The building will have Apex braces. Estimated internal apex clearance is: 3.086m.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width. Brackets are provided so that the Z is bolted through the web.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.

Site Design Specifications

Site – North Coast QLD 4802 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 69.3 m/s; Region C; TC = 2.5; Mt = 1; Mc = 0; Ms = 1; giving a Vdes of 57.3 m/s.
Other Design Factors – No Snow Loading allowed

Pricing at Jan 2024

Kit Price – $23,263.64
GST – $2,326.36
Delivery – FREE*
Pay-on-Time discount  – ($2,560.00)#
TOTAL (inc GST) – $23,030.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.

REFERENCE # : 2307022-3

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.