Details of this Shed
Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 3,000 kg
Span – Main Building: 8 m
Length – 10.8 m (3 Bays: 4.8 m, 2.5 m, 3.5 m)
Height – 4.1 m (Low Side), 4.94 m (High Side)
Roof Type – Skillion, 6 degrees
Roof – ZINCALUME® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – COLORBOND® GUTTER-01. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 3.
Roller Doors – One (1) COLORBOND® steel 4m high x 2.75m wide roller door supplied with a planetary gearing system (roller door is wind rated). Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Door is boxed or steel wrapped for protection during transport. Refer to the Building information for details on Industrial Door Handing.
PA Doors – One (1) single skin Deluxe COLORBOND® steel door with keyed lockset and lever handle to one side;
Dividing Walls – One (1) structural wall coloured red running across the span of the building between bays 1 & 2. COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting. This wall will be the colour selected for internal walls. This wall is structural – they must be installed in the location shown. They cannot be moved at any time.
Solar Panels – Your building has been designed to allow for the loads of a future installation of Solar Panels (by others). The information you have provided is that you require the maximum number of panels on your building. We calculate that you can fit 40 panels on your new steel building. This is typically 14.2kW of Solar Panels. You can of course also put panels on your home or other suitably designed structures to get the maximum benefit from your investment. We have engineered the building for panels to be placed on the left side of the main building.
Open Bays – Two (2) 4.8m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the left-end-wall-mullions have been removed. Refer to the Layout attached.
Bracing – The building will have Knee braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.717m (Left Side), 3.415m (Right Side) .
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – Northern ACT 2903 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45 m/s ; Region A3; TC = 2.5; Mt = 1; Mc = 1; Ms = 1.0; giving a Vdes of 39.2 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.
Pricing at May 2024
Kit Price – $20,663.64
GST – $2,066.36
Delivery – FREE*
Pay-on-Time discount – ($1,710.00)#
TOTAL (inc GST) – $21,020.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2405099
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.