REFERENCE # : 2402187
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2402187
Details of this Shed
Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 3,200 kg
Span – Main Building: 5.5 metres
Length – 20 metres (6 Bays: 3 metres, 3.5 metres, 3.5 metres, 3.33 metres, 3.33 metres, 3.33 metres)
Height – 3 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – UNSLOTTED 115 Quad Gutter. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 3. Right Side = 2 (main building), 3 (leanto).
Roller Doors – Two (2) COLORBOND® steel 2.47m high x 4.27m wide roller doors (roller door is not wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport.
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Two (2) 900h x1200w windows and One (1) 2100h x1800w glass sliding door (the supply of windows is NOT included).
Dividing Walls – One (1) structural wall coloured red running across the span of the building between bays 1 & 2. COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting. This wall will be the colour selected for internal walls. This wall is structural – they must be installed in the location shown. They cannot be moved at any time.
Open Bays – Two (2) 3m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the left-end-wall-mullions have been removed. Refer to the Layout attached.
Bracing – The building will have Knee braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.011m.
Left Lean-to
Span – 1.5m
Drop – No drop
Pitch – 6 degrees
Length – Starting bay 1 for 3 bays
Height of External Lean-to wall – 2.84m
One (1) 3m open bay and Two (2) 3.5m open bays – along the sides of the leanto. Two (2) 1.5m open bays on the ends of the leanto. Refer to Layout (attached) for location & height clearances.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – Southern VIC 3139 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45 m/s; Region A5; TC = 2.13; Mt = 1; Mc = 1; Ms = 1.0; giving a Vdes of 38.5 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.
Pricing at Feb 2024
Kit Price – $23,490.91
GST – $2,349.09
Delivery – FREE*
Pay-on-Time discount – ($2,590.00)#
TOTAL (inc GST) – $23,250.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2402187
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.