REFERENCE # : 2307022
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2307022
Details of this Shed
Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 2,900 kg
Span – Main Building: 7 metres
Length – 14 metres (4 Bays: 4 metres, 4 metres, 4 metres, 2 metres)
Height – 3 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – 150 High Front Quad Gutter – Unslotted . Nominal downpipe spacing = 4m.
PA Doors – One (1) 920mm wide pre-hung double skin COLORBOND® steel door with keyed lockset and lever handle on both sides;
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Four (4) 1500h x1200w windows and One (1) 2100h x2700w glass sliding door (the supply of windows is NOT included).
Dividing Walls – One (1) structural wall coloured red running across the span of the building between portals 3 & 4. COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting. This wall is structural – they must be installed in the location shown. They cannot be moved at any time.
Roof Ventilators – Ridge vent (same colour as roof).
Open Bays – Two (2) 2m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the right-end-wall-mullions have been removed. Refer to the Layout attached.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width. Brackets are provided so that the Z is bolted through the web.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – North Coast QLD 4802 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 69.3 m/s; Region C; TC = 2.5; Mt = 1; Mc = 0; Ms = 1; giving a Vdes of 57.3 m/s.
Other Design Factors – No Snow Loading allowed.
Pricing at July 2023
Kit Price – $22,281.82
GST – $2,228.18
Delivery – FREE*
Pay-on-Time discount – ($1,810.00)#
TOTAL (inc GST) – $22,700.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2307022
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.