REFERENCE # : 2209103
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2209103
Details of this Shed
Weight – Approximately: 3,200 kg
Span – 7.5 metres
Length – 10 metres (3 Bays: 3.5 metres, 3.5 metres, 3 metres)
Height – 4.1 metres
Roof Type – Gable, 15 degree pitch
Roof – ZINCALUME® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Eaves – 0.5 metres (Soffits by others)
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – Big M Gutter. Nominal downpipe spacing = 3.5m.
Roller Doors – Two (2) COLORBOND® steel 3m high x 2.8m wide roller doors (roller door is wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport.
PA Doors – One (1) 2040h x820w COLORBOND® steel door. Single skin metal clad door with COLORBOND® steel facings and fold-down vertical sides for strength and appearance. On a welded RHS frame, the door is pre-hung into a powdercoated frame. Supplied with a Knob/Knob entrance set;
Roof Ventilators – 2 x 300mm Ventilator(s) (same colour as roof).
Bracing – The building will have Knee braces. Minimum internal knee clearances are: Main Building 2.965m.
Mezzanine – One (1) bay, starting at bay Three (3). Height under joist to be 2.6m, with a clearance under the bearer of 2.4m. Steel bearers and joists only. Bearers supported y One (1) mid columns. Stairs, balustrading and timber flooring supplied by others. Allowable floor load is 3.0kPa uniformly distributed. (Suitable for a office for general use or General storage up to 1.2m high – No concentrated loads).
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – Nort East NSW 2479 Australia
Building Class – 10
Importance Level – 2 with a Vr of 57 m/s
Design Wind Criteria – Region B; TC = 2.5; Mt = 1; Ms = 1; giving a Vdes of 47.2 m/s.
Other Design Factors – No Snow Loading allowed. No Earthquake Loading allowed.
Pricing at Sept 2022
Kit Price – $23,381.82
GST – $2,338.18
Delivery – FREE*
Promotional Discount (Early Santa Shed Savings) – ($1,930.00)
TOTAL (inc GST) – $23,790.00
* subject to standard delivery area
REFERENCE # : 2209103
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.