REFERENCE # : 2407020

6m x 15m x 3.2m Garaport Shed with Roof Upgrade for Solar Panels, 1 Roller Door and 1 PA Door

BUY A SHED COURSE:

The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.

REFERENCE # : 2407020

Details of this Shed

Building Class – 10a A non-habitable building including a private garage, carport, shed or the like. (Refer NCC A6G11)
Weight – Approximately: 2,200 kg
Span – Main Building: 6 m
Length – 15 m (4 Bays: 4 m, 3.67 m, 3.67 m, 3.66 m)
Height – 3.2 m
Roof Type – Gable, 10 degrees
Roof – COLORBOND® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – COLORBOND® GUTTER-01. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 2. Right Side = 2.
Roller Doors – One (1) COLORBOND® steel 2.6m high x 5m wide roller door (roller door is not wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Door is boxed or steel wrapped for protection during transport.
PA Doors – One (1) Larnec 2040h x 820w Single skin metal clad pre-hung door with COLORBOND® steel® steel facings and fold-down vertical sides for strength and appearance. Powder coated welded RHS frame. Supplied with a Knob/Lever entrance set. 180 degrees opening and reversible handing;
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Two (2) 900h x1200w windows (supply of the window is NOT included).
Dividing Walls – One (1) structural wall coloured red running across the span of the building between bays 1 & 2. COLORBOND® steel CORODEK® 0.42 BMT (0.47TCT) sheeting. This wall will be the colour selected for internal walls. This wall is structural – they must be installed in the location shown. They cannot be moved at any time.
Solar Panels – Your building has been designed to allow for the loads of a future installation of Solar Panels (by others). The information you have provided is that you require the maximum number of panels on your building. We calculate that you can fit 28 panels on your new steel building. This is typically 9.9kW of Solar Panels. You can of course also put panels on your home or other suitably designed structures to get the maximum benefit from your investment. We have engineered the building for panels to be placed on both sides of the main building.
Open Bays – Two (2) 4m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the left-end-wall-mullions have been removed. Refer to the Layout attached.
Bracing – The building will have Knee braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.211m.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.

Site Design Specifications

Site – South Eastern NSW 2620 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45 m/s ; Region A3; TC = 3.0; Mt = 1; Mc = 1; Ms = 0.84; giving a Vdes of 31.4 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.

Pricing at July 2024

Kit Price – $17,018.18
GST – $1,701.82
Delivery – FREE*
Pay-on-Time discount – ($1,410.00)#
TOTAL (inc GST) – $17,310.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.

REFERENCE # : 2407020

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.