REFERENCE # : 2501044
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2501044
Details of this Shed
Building Class – 1a One or more buildings, which together form a single dwelling. (Refer NCC A6G2)
Weight – Approximately: 2600.00 kg
Span – Main Building: 8 m
Length – 14 m (4 Bays: 3.5 m, 2.5 m, 4.5 m, 3.5 m)
Height – 3 m
Roof Type – Gable, 10 degrees
Roof – COLORBOND® steel CORODEK® 0.42 BMT sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT sheeting, BlueScope
Gutters – COLORBOND® GUTTER-01. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 2. Right Side = 2.
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Two (2) 1500h x1800w windows, One (1) 900h x900w window, Two (2) 2100h x2100w glass sliding doors and Two (2) 900h x1200w windows (the supply of windows and glass sliding doors NOT included).
Vermin Flashing – PVC Vermin Proofing has been included to the perimeter of the building excluding any openings
Solar Panels – Your building has been designed to allow for the loads of a future installation of Solar Panels (by others). The information you have provided is that you require the maximum number of panels on your building. We calculate that you can fit 52 panels on your new steel building. This is typically 18.5kW of Solar Panels. You can of course also put panels on your home or other suitably designed structures to get the maximum benefit from your investment. We have engineered the building for panels to be placed on both sides of the main building.
Bracing – The building will have Apex braces. Estimated internal apex clearance is: 3.236m. Fly Bracing is a U shape to allow for internal linings.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – Central VIC 3467 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45.00 m/s ; Region A1; TC = 2.49; Mt = 1; Mc = 1; Ms = 0.88; giving a Vdes of 34.5 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor. Any plasterboard must be articulated in accordance with ASNZS 1170.4:2007 and the requirements of the NCC: 2022.
Other Design Factors – No Snow Loading allowed.
Pricing at Jan 2025
Kit Price – $18,590.91
GST – $1,859.09
Delivery – FREE*
Pay-on-Time discount – ($2,050.00)#
TOTAL (inc GST) – $18,400.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2501044
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.