Details of this Shed
Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 1,700 kg
Span – Main Building: 6 metres
Length – 10 metres (3 Bays: 4 metres, 3 metres, 3 metres)
Height – 3 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – Squareline Gutter – WA Only – Unslotted . Nominal downpipe spacing = 4m.
Roller Doors – Two (2) COLORBOND® steel 2.57m high x 2.6m wide roller doors (roller door is wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport.
PA Doors – One (1) 2040h x820w COLORBOND® steel door. Single skin metal clad door with COLORBOND® steel facings and fold-down vertical sides for strength and appearance. On a welded RHS frame, the door is pre-hung into a powdercoated frame. Supplied with a Knob/Knob entrance set;
Dividing Walls – One (1) structural wall coloured red running across the span of the building between portals 1 & 2. COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting. This wall is structural – they must be installed in the location shown. They cannot be moved at any time.
Open Bays – Two (2) 4m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the left-end-wall-mullions have beenremoved. Refer to the Layout attached.
Bracing – The building will have Knee braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.442m.
Roof Purlins & Wall Girts – Tophat sections with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – Southern WA 6346 Australia
NCC Version – NCC 2019. This is only valid until April 2024. Confirm with your certifier.
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45 m/s; Region A1; TC = 2.5; Mt = 1; Ms = 1; giving a Vdes of 39.2 m/s.
Other Design Factors – No Snow Loading allowed.
Pricing at July 2023
Kit Price – $14,136.36
GST – $1,413.64
Delivery – $1,090.00
Pay-on-Time discount – ($1,230.00)#
TOTAL (inc GST) – $15,410.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2307057
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.