REFERENCE # : 2410141
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2410141
Details of this Shed
Building Class – 10a A non-habitable building including a private garage, carport, shed or the like. (Refer NCC A6G11)
Weight – Approximately: 2,200 kg
Span – Main Building: 4 m
Length – 12 m (3 Bays: 3 m, 3 m, 6 m)
Height – 2.7 m (Low Side), 3.12 m (High Side)
Roof Type – Skillion, 6 degrees
Roof – ZINCALUME® steel CORODEK® 0.42 BMT sheeting, BlueScope
Walls & Trims – COLORBOND® steel CORODEK® 0.42 BMT sheeting, BlueScope
Gutters – COLORBOND® GUTTER-02. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 3.
Roller Doors – One (1) COLORBOND® steel 2.5m high x 5m wide roller door (roller door is wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. One (1) COLORBOND® steel 2.1m high x 2.4m wide roller door (roller door is wind rated). Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport.
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Two (2) 1200h x1800w windows, Two (2) 1200h
x1200w windows and One (1) 900h x1800w window (the supply of windows and glass sliding doors NOT included).
Bracing – The building will have Knee braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.074m (Left Side), 2.432m (Right Side).
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width. Brackets are provided so that the Z is bolted through the web.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – Far North QLD 4879 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 65.7 m/s ; Region C; TC = 3.0; Mt = 1; Mc = 1.05; Ms = 0.85; giving a Vdes of 43.8 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.
Pricing at Oct 2024
Kit Price – $17,709.09
GST – $1,770.91
Delivery – FREE*
Pay-on-Time discount – ($1,470.00)#
TOTAL (inc GST) – $18,010.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2410141
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.