REFERENCE # : 2306004
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2306004
Details of this Shed
Building Class – 8 A building in which the production, assembling, altering, repairing, packing, finishing, or cleaning of goods or produce for sale takes place or laboratory. (Refer NCC A6G9)
Weight – Approximately: 26,400 kg
Span – Main Building: 28 metres
Length – 40 metres (8 Bays of 5 metres each)
Height – 5 metres
Roof Type – Gable, 10 degree pitch
Roof – ZINCALUME® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Roller Doors – Three (3) COLORBOND® steel 5m high x 5m wide roller doors supplied with a planetary gearing system (roller door is wind rated). Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport. Refer to the Building information for details on Industrial Door Handing.
PA Doors – Three (3) 920mm wide pre-hung double skin COLORBOND® steel doors with keyed lockset and lever handle on both sides;
Skylights – Eight (8) sheets of 2400gsm Industrial Grade Translucent (Opal) Fibreglass. Four (4) on left side of steel building roof. Four (4) on right side of steel building roof.
Roof Ventilators – Ridge vent (same colour as roof).
Bracing – The building will have Knee and Apex braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.760m. Estimated internal apex clearance is: 5.916m.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – Central VIC 3355 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45 m/s; Region A1; TC = 3.0; Mt = 1; Mc = 0; Ms = 1.0; giving a Vdes of 37.4 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.
Pricing at June 2023
Kit Price – $178,918.18
GST – $17,891.82
Delivery – FREE*
Pay-on-Time discount – ($14,770.00)#
TOTAL (inc GST) – $182,040.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2306004
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.