Details of this Shed
Building Class – 10a A non-habitable building including a private garage, carport, shed or the like. (Refer NCC A6G11)
Weight – Approximately: 5,100 kg
Span – Main Building: 14 m
Length – 11 m (3 Bays: 3.67 m, 3.67 m, 3.66 m)
Height – 3.7 m
Roof Type – Gable, 10 degrees
Roof – COLORBOND® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – MONUMENT® GUTTER-05. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 5. Right Side = 4 (main building), 5 (leanto).
Roller Doors – Two (2) COLORBOND® steel 2.6m high x 2.85m wide roller doors (with 2 motorised unit (GDO-6 V3 (or similar) with 2 remote handpieces), roller door is wind rated). One (1) COLORBOND® steel 3.4m high x 2.85m wide roller door (with 1 motorised unit (Grifco LR Drive (or similar) with battery backup, 2 remote handpieces and a wireless wall control), roller door is wind rated). An internal chain drive has been
added to the door to assist with opening and closing the door at heights. One (1) COLORBOND® steel 2.6m high x 2.85m wide roller door (roller door is wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport. Refer to the Building information for details on Industrial Door Handing.
PA Doors – One (1) single skin Deluxe COLORBOND® steel door with keyed lockset and lever handle to one side;
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit One (1) 2100h x2400w glass sliding door (supply of the window is NOT included).
Skylights – Three (3) sheets of 2400gsm Industrial Grade Translucent (Opal) Fibreglass. Three (3) on the left side of steel building roof.
Vermin Flashing – PVC Vermin Proofing has been included to the perimeter of the building excluding any openings
Bracing – The building will have Knee and Apex braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.049m. Estimated internal apex clearance is: 4.203m. Side Walls bracing will be supplied as cable.
Left Lean-to
Span – 3.5m
Drop – No drop
Pitch – 6 degrees
Length – Starting bay 1 for 3 bays
Height of External Lean-to wall – 3.33m
Two (2) 3.67m open bays and One (1) 3.66m open bay – along the sides of the leanto. Two (2) 3.5m open bays on the ends of the leanto. Refer to Layout
(attached) for location & height clearances.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – North Eastern NSW 2482 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 57 m/s ; Region B; TC = 2.5; Mt = 1; Mc = 1; Ms = 1.0; giving a Vdes of 47.1 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed
Pricing at June 2024
Kit Price – $41,645.45
GST – $4,164.55
Delivery – FREE*
Pay-on-Time discount – ($3,440.00)#
TOTAL (inc GST) – $42,370.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2306084-7
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.