REFERENCE # : 2104106
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2104106
Details of this Shed
Weight – Approximately: 10,600 kg
Span – 12 metres
Length – 20 metres (4 Bays of 5 metres each)
Height – 5.5 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Roller Doors – One (1) COLORBOND® steel 4.5m high x 5m wide roller door supplied with a
planetary gearing system (roller door is wind rated). Three (3) COLORBOND® steel
3m high x 2.95m wide roller doors (roller door is wind rated). Refer to the General
Specification (# Access Doors) in relation to opening sizes. The Roller Doors are
boxed or steel wrapped for protection during transport. Refer to the Building
information for details on Industrial Door Handing.
PA Doors – One (1) 2040 x 820 COLORBOND® steel door. Single skin metal clad door with
COLORBOND® steel facings and fold-down vertical sides for strength and
appearance. On a welded RHS frame, the door is pre-hung into a powdercoated
frame. Supplied with a Knob/Knob entrance set;
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Two
(2) 900×1800 windows and One (1) 2100×2100 glass sliding door (the supply of
windows is NOT included).
Bracing – The building will have Knee and Apex braces. Minimum internal knee clearances are:
Main Building 3.640m. Minimum internal apex clearance is: 5.731m.
Mezzanine – One (1) bay, starting at bay Four (4). Height under joist to be 2.6m, with a
clearance under the bearer of 2.35m. Steel bearers and joists only. Bearers
supported by Two (2) mid columns. Stairs, balustrading and timber flooring supplied
by others. Allowable floor load is 1.5kPa uniformly distributed. (Suitable for General
Storage up to 600mm high- No concentrated loads)
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay
width. Brackets are provided so that the Z is bolted through the web.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – North QLD 4880 Australia
Building Class – 10
Importance Level – 2 with a Vr of 69.3 m/s
Design Wind Criteria – Region C; TC = 2.5; Mt = 1; Ms = 1; giving a Vdes of 57.3 m/s.
Other Design Factors – No Snow Loading allowed. No Earthquake Loading allowed.
PRICING AT April 2021
Kit Price – $57,945.45
GST – $5,794.55
Delivery – FREE*
Promotional Discount (G.A.S Sale) – ($6,380.00)
TOTAL (inc GST) – $57,360.00
*subject to standard delivery area
REFERENCE # : 2104106
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.