REFERENCE # : 2205089
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2205089
Details of this Shed
Weight – Approximately: 3,500 kg
Span – 4 metres
Length – 12 metres (3 Bays of 4 metres each)
Height – 4.2 metres
Roof Type – Gable, 22.5 degree pitch
Roof – ZINCALUME® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – ZINCALUME® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – 115 High Front quad gutter – Unslotted . Nominal downpipe spacing = 4m.
Roller Doors – One (1) ZINCALUME® steel 3m high x 2.95m wide roller door (roller door is wind rated). Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Door is boxed or steel wrapped for protection during transport.
PA Doors – One (1) 2040h x820w ZINCALUME® steel steel door. Single skin metal clad door with COLORBOND® steel facings and fold-down vertical sides for strength and appearance. On a welded RHS frame, the door is pre-hung into a powdercoated frame. Supplied with a Knob/Knob entrance set;
Stable Boxes – Additional support posts (2 per box) to allow the fixing of timber panels (by others) to create Six (6) stable boxes. Three (3) adjoining each other on the left side wall and Three (3) on the right side wall.
Open Bays – Six (6) 4m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Bracing – The building will have Knee and Apex braces. Minimum internal knee clearances are: Main Building 3.364m. Minimum internal apex clearance is: 4.505m.
Left & Right Lean-to
Span – 4m
Drop – 0.6 metres from eave height
Pitch – 10 degrees
Length – Starting bay 1 for 3 bays
Height of External Lean-to wall – 2.9m
Left end sheeting – Yes
Right end sheeting – Yes
Outside wall sheeting – Yes
Inside wall sheeting – No
Roof Purlins & Wall Girts– Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay
width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – South East SA 5353 Australia
Building Class – 7
Importance Level – 2 with a Vr of 45 m/s
Design Wind Criteria – Region A1; TC = 2.5; Mt = 1; Ms = 1.0; giving a Vdes of 39.2 m/s.
Other Design Factors – No Snow Loading allowed. No Earthquake Loading allowed.
PRICING AT MAY 2022
Kit Price – $21,963.64
GST – $2,196.36
Delivery – FREE*
Promotional Discount (EOFY Sale) – ($1,820.00)
TOTAL (inc GST) – $22,340.00
* subject to standard delivery area
REFERENCE # : 2205089
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.