Weight – Approximately: 3,400 kg
Span – 8 metres
Length – 10 metres (2 Bays: 4 metres, 6 metres)
Height – 4 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Roller Doors – Two (2) COLORBOND® steel 3m high x 5m wide roller doors (roller door is not wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport.
PA Doors – One (1) 2040h x820w COLORBOND® steel door. Single skin metal clad door with COLORBOND® steel facings and fold-down vertical sides for strength and appearance. On a welded RHS frame, the door is pre-hung into a powdercoated frame. Supplied with a Knob/Knob entrance set;
Roof Ventilators – 2 x 300mm Ventilator(s) (same colour as roof).
Bracing – The building will have Knee and Apex braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.805m. Estimated internal apex clearance is: 4.081m.
Left Lean-to
Span – 3.5m
Drop – No drop
Pitch – 6 degrees
Length – Starting bay 2 for 1 bays
Height of External Lean-to wall – 3.63m
One (1) 6m open bay – along the sides of the leanto. Two (2) 3.5m open bays on the ends of the leanto. Refer to Layout (attached) for location & height clearances.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – South East QLD 4300 Australia
Building Class – 10
NCC Version – The Engineer to select NCC 2019 or NCC 2022 as a Performance Standard
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 57 m/s; Region B; TC = 2.5; Mt = 1; Ms = 1; giving a Vdes of 47.2 m/s.
Other Design Factors – No Snow Loading allowed.
Pricing at Feb 2023
Kit Price – $24,945.45
GST – $2,494.55
Delivery – FREE*
Promotional Discount – ($2,060.00)
TOTAL (inc GST) – $25,380.00
* subject to standard delivery area
REFERENCE # : 2302144
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.