REFERENCE # : 2104179

BUY A SHED COURSE:

The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.

REFERENCE # : 2104179

Details of this Shed 

Weight – Approximately: 32,400 kg
Span – 30 metres
Length – 60 metres (10 Bays of 6 metres each)
Height – 4.8 metres
Roof Type – Gable, 10 degree pitch
Roof – ZINCALUME® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – ZINCALUME® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Open Bays – Twenty (20) 6m open bays – along the sides of the steel building. Refer to Layout
(attached) for location & height clearances.
Open Gable-Ends – Steel building has sheeting as shown whilst the end-wall-mullions have been
removed. Refer to the Layout attached.
Bracing – The building will have Knee and Apex braces. Minimum internal knee clearances are:
Main Building 2.401m. Minimum internal apex clearance is: 5.892m.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay
width.
Fixing to Concrete – Columns embedded into the concrete footings.

Site Design Specifications 

Site – South VIC 3981 Australia
Building Class – 10
Importance Level – 2 with a Vr of 45 m/s
Design Wind Criteria – Region A5; TC = 2.5; Mt = 1; Ms = 1; giving a Vdes of 39.2 m/s.
Other Design Factors – No Snow Loading allowed. No Earthquake Loading allowed.
Roof Only – Less than 50% filled under

PRICING AT APRIL 2021

Kit Price – $135,163.64
GST – $13,516.36
Delivery – FREE*
Promotional Discount (G.A.S Sale) – ($14,870.00)
TOTAL (inc GST) – $133,810.00
* subject to standard delivery area

REFERENCE # : 2104179

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.