REFERENCE # : 2309203

5.5m x 9m x 2.5m Region B Home Workshop Shed With Insulation

BUY A SHED COURSE:

The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.

REFERENCE # : 2309203

Details of this Shed

Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 1,600 kg
Span – Main Building: 5.5 metres
Length – 9 metres (3 Bays of 3 metres each)
Height – 2.5 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – 150 High Front Quad Gutter – Unslotted . Nominal downpipe spacing = 3m.
Roller Doors – One (1) COLORBOND® steel 2.2m high x 2.95m wide roller door (roller door is wind rated). Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Door is boxed or steel wrapped for protection during transport.
PA Doors – Two (2) 2040h x820w COLORBOND® steel doors. Single skin metal clad door with COLORBOND® steel facings and fold-down vertical sides for strength and appearance. On a welded RHS frame, the door is pre-hung into a powdercoated frame. Supplied with a Knob/Knob entrance set;
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit One (1) 900h x1800w window (supply of the window is NOT included).
Insulation – Lightweight 50-60mm Insulated Roofing Blanket, or equivalent performance specification. Insulation is a glass wool blanket with a reinforced laminated thermofoil face to one side. (Performance specification (R Value) change dependent on the ventilation. Insulation to the roof of the main building. Safety wire is provided to the roof area only.
Roof Purlins & Wall Girts – Tophat sections with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.

Site Design Specifications

Site – Central Coast QLD 4570 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 57 m/s; Region B; TC = 2.5; Mt = 1.08; Mc = 0; Ms = 1.0; giving a Vdes of 50.9 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.

Pricing at Oct 2023

Kit Price – $14,118.18
GST – $1,411.82
Delivery – FREE*
Pay-on-Time discount – ($1,170.00)#
TOTAL (inc GST) – $14,360.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.

REFERENCE # : 2309203

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.