REFERENCE # : 2311142-1

22.5m x 15m x 4.3m Aircraft Hanger Shed With 4 Outrigger Doors

BUY A SHED COURSE:

The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.

REFERENCE # : 2311142-1

Details of this Shed

Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 6,500 kg
Span – Main Building: 15 metres; total span: 22.5 meters. Refer to #Outriggers in ‘General Specifications’
Length – 15 metres (4 Bays of 3.75 metres each)
Height – 4.3 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – GUTTER-115-Unslotted. Nominal downpipe spacing = 3.8m.
PA Doors – One (1) 2040h x820w COLORBOND® steel door. Single skin metal clad door with COLORBOND® steel facings and fold-down vertical sides for strength and appearance. On a welded RHS frame, the door is pre-hung into a powdercoated frame. Supplied with a Knob/Knob entrance set;
Outrigger Doors – Four (4) of 3.992m high by 3.75m wide doors are supplied in kit form, cut to size
for easy assembly. Refer to Access Doors in the General Specifications. Two doors opening to the right and two doors opening to the left. The opening width behind the Outrigger Doors will be approx. 14.4 meters. Concrete piers to the Outrigger columns and braces at ground level with a strip footing to support the lower door tracks.
Open Gable-Ends – Steel building has sheeting as shown whilst the left-end-wall-mullions have been
removed. Refer to the Layout attached.
Bracing – The building will have Knee and Apex braces, except on the left end to accommodate Outrigger Doors. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.494m. Estimated internal apex clearance is: 4.864m.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.

Site Design Specifications

Site – Eastern NSW 2850 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 45 m/s; Region A1; TC = 2.5; Mt = 1; Mc = 1; Ms = 1.0; giving a Vdes of 39.2 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in
the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.

Pricing at Nov 2023

Kit Price – $49,527.27
GST – $4,952.73
Delivery – FREE*
Pay-on-Time discount – ($4,090.00)#
TOTAL (inc GST) – $50,390.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.

REFERENCE # : 2311142-1

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.