REFERENCE # : 2306152
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2306152
Details of this Shed
Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 4,200 kg
Span – Main Building: 9.5 metres
Length – 9 metres (3 Bays: 2 metres, 3.5 metres, 3.5 metres)
Height – 3.5 metres (Low Side), 4.5 metres (High Side)
Roof Type – Skillion, 06 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Roller Doors – One (1) COLORBOND® steel 3m high x 3m wide roller door (roller door is wind rated). Door height will necessitate a manual system (by owner) to reach the top of the door for opening and closing. One (1) COLORBOND® steel 3.4m high x 3m wide roller door supplied with a planetary gearing system (roller door is wind rated). An internal chain drive has been added to the door to assist with opening and closing the door at heights. Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport. Refer to the Building information for details on Industrial Door Handing.
PA Doors – Two (2) 2040h x820w COLORBOND® steel doors. Single skin metal clad door with COLORBOND® steel facings and fold-down vertical sides for strength and appearance. On a welded RHS frame, the door is pre-hung into a powdercoated frame. Supplied with a Knob/Knob entrance set;
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit One (1) 2100h x2100w glass sliding door, Two (2) 900h x1200w windows and Two (2) 900h x1500w windows (the supply of windows is NOT included).
Dividing Walls – One (1) structural wall coloured red running across the span of the building between portals 1 & 2. COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting. This wall is structural – they must be installed in the location shown. They cannot be moved at any time.
Insulation – Lightweight 50-60mm Insulated Roofing Blanket, or equivalent performance specification. Insulation is a glass wool blanket with a reinforced laminated thermofoil face to one side. (Performance specification (R Value) change dependent on the ventilation. Insulation to the roof, left side, right side, left end, right end of the main building, to the roof, right side, right end of the right leanto. Safety wire is provided to the roof area only.
Vermin Flashing – PVC Vermin Proofing has been included to the perimeter of the building excluding any openings
Bracing – The building will have Knee braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.525m (Left Side), 3.412m (Right Side) .
Right Lean-to
Span – 4m
Drop – 1 metres from eave height
Pitch – 06 degrees
Length – Starting bay 1 for 3 bays
Height of External Lean-to wall – 3.08m
One (1) 2m open bay – along the sides of the leanto. One (1) 4m open bays on the ends of the leanto. Refer to Layout (attached) for location & height clearances.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – Central Coast QLD 4570 Australia
Building Orientation – Left Side of building orientated to 0° (northerly direction)
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 57 m/s; Region B; TC = 2.5; Mt = 1; Mc = 0; Ms = 1; giving a Vdes of 47.2 m/s.
Other Design Factors – No Snow Loading allowed
Pricing at June 2023
Kit Price – $35,554.55
GST – $3,555.45
Delivery – FREE*
Pay-on-Time discount – ($2,900.00)#
TOTAL (inc GST) – $36,210.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2306152
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.