REFERENCE # : 2402252-4
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2402252-4
Details of this Shed
Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 6,800 kg
Span – Main Building: 10 metres
Length – 20 metres (5 Bays of 4 metres each)
Height – 4 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – 150 Hi Front Quad Gutter. We have calculated the number of [Supplied by Others] downpipes required for: Left Side = 5. Right Side = 5.
Roller Doors – Four (4) COLORBOND® steel 3.5m high x 3m wide roller doors supplied with a planetary gearing system (roller door is wind rated). An internal chain drive has been added to the door to assist with opening and closing the door at heights. Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport. Refer to the Building information for details on Industrial Door Handing.
PA Doors – One (1) 2040h x 820w COLORBOND® steel door. Single skin metal clad door with COLORBOND® steel facings and fold-down vertical sides for strength and appearance. On a welded RHS frame, the door is pre-hung into a powdercoated frame. Supplied with a Knob/Lever entrance set;
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Two (2) 2100h x1800w glass sliding doors and Three (3) 900h x1200w windows (the supply of windows is NOT included).
Bracing – The building will have Knee and Apex braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.478m. Estimated internal apex clearance is: 4.205m.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width. Brackets are provided so that the Z is bolted through the web.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – North Coast QLD 4865 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 64.5 m/s; Region C; TC = 2.5; Mt = 1; Mc = 1.05;
Ms = 1.0; giving a Vdes of 53 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.08 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.
Pricing at Mar 2024
Kit Price – $57,727.27
GST – $5,772.73
Delivery – FREE*
Pay-on-Time discount – ($4,770.00)#
TOTAL (inc GST) – $58,730.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2402252-4
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.