REFERENCE # : 2310096
BUY A SHED COURSE:
The ShedBlog has launched a course on the Teachable platform that will help shed buyers avoid making costly mistakes when buying a shed. Enroll here.
REFERENCE # : 2310096
Details of this Shed
Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 5,800 kg
Span – Main Building: 10 metres
Length – 20 metres (5 Bays of 4 metres each)
Height – 3 metres
Roof Type – Gable, 10 degree pitch
Roof – COLORBOND® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel CORODEK® 0.42 BMT (0.47TCT) sheeting, BlueScope
Gutters – 150 High Front Quad Gutter – Unslotted . Nominal downpipe spacing = 4m.
Roller Doors – Four (4) COLORBOND® steel 2.58m high x 2.6m wide roller doors (with 4 motorised unit (GDO-6 V3 (or similar) with 2 remote handpieces), roller door is wind rated). Refer to the General Specification (# Access Doors) in relation to opening sizes. The Roller Doors are boxed or steel wrapped for protection during transport.
PA Doors – One (1) 2040h x820w COLORBOND® steel door. Single skin metal clad door with COLORBOND® steel facings and fold-down vertical sides for strength and appearance. On a welded RHS frame, the door is pre-hung into a powdercoated frame. Supplied with a Knob/Knob entrance set;
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit One (1) 2100h x1800w glass sliding door and Two (2) 900h x1200w windows (the supply of windows is NOT included).
Bracing – The building will have Knee and Apex braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.089m. Estimated internal apex clearance is: 3.334m.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width. Brackets are provided so that the Z is bolted through the web.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.
Site Design Specifications
Site – Far North QLD 4871 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 69.3 m/s; Region C; TC = 2.5; Mt = 1; Mc = 0; Ms = 1; giving a Vdes of 57.3 m/s.
Other Design Factors – No Snow Loading allowed.
Pricing at Oct 2023
Kit Price – $45,836.36
GST – $4,583.64
Delivery – FREE*
Pay-on-Time discount – ($3,790.00)#
TOTAL (inc GST) – $46,630.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.
REFERENCE # : 2310096
Specific Inclusions
- Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
- A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
- Engineering certification of the steel building to the appropriate Australian Standards.
- Slab or Pier designs for soil classes A, S, M, H1 and H2.
- Materials, as nominated above, supplied as per the attached General Specification”.
- BlueScope – product warranties of up to 15 years apply.
Specific Exclusions
- Drawings, other than detailed above.
- Consent authority including any building, development or construction certificate application(s).
- Construction of the steel building and any foundations (the building is supplied as a kit).
- Insurance of the steel building once delivered to site or collected from the depot.