Details of this Shed

Building Class – 10 A non-habitable building or structure. (Refer NCC A6G11)
Weight – Approximately: 5,300 kg
Span – Main Building: 8 metres
Length – 17 metres (5 Bays: 4 metres, 4 metres, 3 metres, 3 metres, 3 metres)
Height – 3 metres (Low Side), 3.84 metres (High Side)
Roof Type – Skillion, 06 degree pitch
Roof – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Walls & Trims – COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting, BlueScope
Window Openings – Materials to frame up for window opening(s) including a header flashing to suit Two (2) 900h x1200w windows and Three (3) 2100h x2100w glass sliding doors (the supply of windows is NOT included).
Dividing Walls – One (1) structural wall coloured red running across the span of the building between bays 2 & 3. COLORBOND® steel TRIMCLAD® 0.42 BMT (0.47TCT) sheeting. This wall will be the colour selected for internal walls. This wall is structural – they must be installed in the location shown. They cannot be moved at any time.
Insulation – Lightweight 50-60mm Insulated Roofing Blanket, or equivalent performance specification. Insulation is a glass wool blanket with a reinforced laminated thermofoil face to one side. (Performance specification (R Value) change dependent on the ventilation. Insulation to the roof of the main building. Safety wire is provided to the roof area only.
Vermin Flashing – Metal Vermin Flashing has been included to the perimeter of the building excluding any openings.
Open Bays – Six (6) 3m open bays – along the sides of the steel building. Refer to Layout (attached) for location & height clearances.
Bracing – The building will have Knee braces. Clearances are subject to the engineer’s final design requirements. Estimated internal knee clearances are: Main Building 2.123m (Left Side), 2.865m (Right Side) .
Right Lean-to
Span – 2m
Drop – 0.46 metres from eave height
Pitch – 6 degrees
Length – Starting bay 1 for 5 bays
Height of External Lean-to wall – 3.17m
Two (2) 4m open bays and Three (3) 3m open bays – along the sides of the leanto. Two (2) 2m open bays on the ends of the leanto. Refer to Layout (attached) for location & height clearances.
Roof Purlins & Wall Girts – Z sections bolted to rafters & columns with a minimum overlap of 10% of the bay width. Brackets are provided so that the Z is bolted through the web.
Fixing to Concrete – Screw-Bolts fitted after concrete is cured.

Site Design Specifications

Site – Northern NT 0840 Australia
NCC Version – NCC 2022
Design Wind Criteria for the Highest Cardinal Direction – Importance Level 2 with a Vr of 65.7 m/s; Region C; TC = 2.58; Mt = 1; Mc = 1.05; Ms = 1.0; giving a Vdes of 53.6 m/s.
Earthquake – An Earthquake Acceleration Co-efficient (Z) of up to 0.09 has been allowed for in the design of the building, however wind is the determining design factor.
Other Design Factors – No Snow Loading allowed.

Pricing at Jan 2024

Kit Price – $38,227.27
GST – $3,822.73
Pay-on-Time discount – ($4,210.00)#
Loading of Truck – Free
TOTAL (inc GST) – $37,840.00
* subject to standard delivery area
#Pay-on-Time discount is applied so long as the final payment is received 10 working days prior to the advised delivery date.

REFERENCE # : 2205074-4

Specific Inclusions

  • Determination of the design criteria by the engineer. This includes assessment in 8 cardinal directions to determine the site design wind speed based on the building orientation.
  • A comprehensive step by step Construction Kit. This kit is specific to your building and gives step by step, simple to follow instructions on how to build your building.
  • Engineering certification of the steel building to the appropriate Australian Standards.
  • Slab or Pier designs for soil classes A, S, M, H1 and H2.
  • Materials, as nominated above, supplied as per the attached General Specification”.
  • BlueScope – product warranties of up to 15 years apply.

Specific Exclusions

  • Drawings, other than detailed above.
  • Consent authority including any building, development or construction certificate application(s).
  • Construction of the steel building and any foundations (the building is supplied as a kit).
  • Insurance of the steel building once delivered to site or collected from the depot.